Heat Pump vs Furnace Operating Cost Calculator

Compare the energy cost of delivering the same useful heat with an electric heat pump or natural-gas furnace. No annual heating load needed.

Your energy prices and equipment

Example price only. Use the marginal price for additional heating electricity, including applicable delivery charges.

Example price only. One therm is 100,000 BTU. Use your marginal natural-gas usage price, not the whole bill divided by usage.

COP is how many units of heat the heat pump delivers per unit of electricity used. COP 3 means three units of heat per unit of electricity; this default is an example, not a winter forecast.

Use the furnace’s AFUE rating as an approximation of fuel-to-heat efficiency. Example: 90 means 90% of fuel energy becomes useful heat.

Leave blank for the basic comparison. Enter useful heat needed, not gas input energy. No home heating load is assumed.

How it works

We compare the energy each system needs to deliver 100,000 BTU of useful heat. A heat pump with a higher COP supplies more heat from each kWh; a furnace with higher efficiency supplies more heat from each therm of gas. We apply your prices to that energy use.

Break-even COP is the heat-pump performance needed to match the furnace’s energy cost. If you enter a seasonal useful heating need, we scale both costs to that same amount of heat.

Understanding the comparison

COP is heat delivered divided by electricity used in the same energy units. Heat-pump COP varies with outdoor temperature, equipment, system sizing and operating conditions. Colder weather can lower COP and change which system costs less. One COP does not describe every hour of a winter; do not enter HSPF or HSPF2 directly as COP.

Use marginal energy prices for additional heating. Electric bills can include fixed charges, delivery charges and tiered rates; gas bills can include fixed charges and taxes. Fixed charges do not scale with heat and are excluded here. Include applicable variable charges in the rate you enter.

This compares heat-pump electricity with furnace fuel. Furnace fan electricity, supplemental resistance heat and distribution losses are not separately modeled. Use a representative system COP and furnace efficiency where possible. The same useful-heat target is assumed for both systems.

This does not include installation costs, maintenance, lifespan, rebates, tax credits or financing. It does not size equipment or recommend changing a thermostat’s changeover setting. Neither technology is universally cheaper.

Background: U.S. Department of Energy heat-pump guidance.

Estimate only. Compare your actual energy rates and equipment performance before making heating decisions.